3. Installation
3-27
Festo P.BE-SPC11-SYS-EN en 1406e
Outputs on the 15-pin “Control” plug (O = output)
Pin
Pin assignment and core colours
Description
9
O5
– Error
1)
black
Factory setting:
– Provides a 1-signal when an error occurs
(see chapter 5).
– Provides a 0-signal in the normal operating state
10
O4
– P.04
2)
violet
Factory setting:
– Supplies a 1-signal if the moveable mass is in
the taught intermediate position P.04.
– Supplies a 1-signal for 50 ms if intermediate
position P.04 is overrun.
11
O3
P.03
grey-pink
– Supplies a 1-signal if the moveable mass is in
the taught intermediate position P.03.
– Supplies a 1-signal for 50 ms if intermediate
position P.03 is overrun.
12
O2
P.02
red-blue
– Supplies a 1-signal if the moveable mass is in
end position P.02.
13
O1
P.01
white-green
– Supplies a 1-signal if the moveable mass is in
end position P.01 (on the side with the electrical
connection for the potentiometer).
1)
Function of O5 can be configured (see section 4.2.3); Error (factory setting) or Ready
2)
Function of O4 can be configured (see section 4.2.3); P.04 (factory setting) or Stop
Line voltage on the 15-pin “Control” plug
Pin
Pin assignment and core colours
Description
14
–
0 V
brown-green
0 V
15
–
24 V supply
white-yellow
DC +24 V (tolerance -10 % to + 25 %)