3. Installation

3-27

Festo P.BE-SPC11-SYS-EN en 1406e

Outputs on the 15-pin “Control” plug (O = output)

Pin

Pin assignment and core colours

Description

9

O5

– Error

1)

black

Factory setting:
– Provides a 1-signal when an error occurs

(see chapter 5).

– Provides a 0-signal in the normal operating state

10

O4

– P.04

2)

violet

Factory setting:
– Supplies a 1-signal if the moveable mass is in

the taught intermediate position P.04.

– Supplies a 1-signal for 50 ms if intermediate

position P.04 is overrun.

11

O3

P.03

grey-pink

– Supplies a 1-signal if the moveable mass is in

the taught intermediate position P.03.

– Supplies a 1-signal for 50 ms if intermediate

position P.03 is overrun.

12

O2

P.02

red-blue

– Supplies a 1-signal if the moveable mass is in

end position P.02.

13

O1

P.01

white-green

– Supplies a 1-signal if the moveable mass is in

end position P.01 (on the side with the electrical
connection for the potentiometer).

1)

Function of O5 can be configured (see section 4.2.3); Error (factory setting) or Ready

2)

Function of O4 can be configured (see section 4.2.3); P.04 (factory setting) or Stop

Line voltage on the 15-pin “Control” plug

Pin

Pin assignment and core colours

Description

14

0 V

brown-green

0 V

15

24 V supply

white-yellow

DC +24 V (tolerance -10 % to + 25 %)