A. Start-up via digital inputs/outputs

A-8

Festo P.BE-SPC11-SYS-EN en 1406e

A.2.3 Teaching the intermediate position time dependency diagram

I5: +/}
I7: {/-

1
0

1
0

Drive is moving

O3/4:
Po.3/4

1
0

1
0

I8: Remote

min. 20 ms

1
0

I6: Enter

min. 2 s

1

2

O5:
Error/Ready

*)

*)

Function of the O5 output can be configured (see chapter 4.2.3); Error (factory setting) or Ready

1

Drive moves as long as the
corresponding signal (I5 or I7) is
present

2

Save current position as intermediate
position (switch-on time min. 2 s)