Festo Контроллер крайних положений SPC11 User Manual
Page 130
A. Start-up via digital inputs/outputs
A-8
Festo P.BE-SPC11-SYS-EN en 1406e
A.2.3 Teaching the intermediate position time dependency diagram
I5: +/}
I7: {/-
1
0
1
0
Drive is moving
O3/4:
Po.3/4
1
0
1
0
I8: Remote
min. 20 ms
1
0
I6: Enter
min. 2 s
1
2
O5:
Error/Ready
*)
*)
Function of the O5 output can be configured (see chapter 4.2.3); Error (factory setting) or Ready
1
Drive moves as long as the
corresponding signal (I5 or I7) is
present
2
Save current position as intermediate
position (switch-on time min. 2 s)
Fig. A/4: Teaching the intermediate position time dependency diagram