4. Commissioning

4-48

Festo P.BE-SPC11-SYS-EN en 1406e

Example: Target position = Pos2

1

Drive
(here linear drive
type DGP-...-...)

1

P.01

P.03

P.02

P.01

P.03

P.02

Fig. 4/10: Premature change of direction (example with linear drive)

The output that signals reaching the intermediate position
(here O3) can, if needed, be wired directly to the correspon-
ding input (here I1, for P.01).