Product-specific terms and abbreviations – Festo Контроллер крайних положений SPC11 User Manual
Page 13
Contents and general instructions
XI
Festo P.BE-SPC11-SYS-EN en 1406e
Product-specific terms and abbreviations
The following product-specific abbreviations are used in this
manual:
Term/abbreviation
Meaning
0-signal
Input or output supplies 0 V
1-signal
Input or output supplies 24 V
Absolute path
measuring system
Path measuring system with fixed (absolute) assignment of measurement
variable and reading
Amplification stage
The amplification stage influences the acceleration behaviour of the drive,
for example. The amplification stage should usually be set as specified in
the “Drive-Specific Supplement” manual. If the positioning behaviour is
later optimised, only the cushioning stage should be modified.
Cushioning stage
The positioning behaviour is determined by the amplification and cushioning
stages. The cushioning stage serves to optimise the approach behaviour
when moving to the end positions.
Drive
The term “drive” is used in this manual for the linear unit (DGP(I)(L)-...),
cylinder (DNC(I)-...) or rotary drive (DSMI).
I
Digital input
Incremental path
measuring system
Path measuring system in which the measurement variable refers to a
reference point and is determined by counting equally large measurement
steps (increments).
O
Digital output
Parameters
Parameters which must be set in order that the system can be operated.
The amplification stage, the cushioning stage and the system parameter
belong here.
PLC/IPC
Programmable Logic Controller/Industrial PC
System parameters
Characteristic value which describes the system structure, the features and
components of the drive used.
Teach procedure
During the teach procedure, the SPC11 checks the set parameters, learns
the position of the mechanical fixed stops as well as various characteristic
system values and saves these in the integrated EEPROM.