beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 18

background image

1. Summary of components

1-4

Festo P.BE-SPC11-SYS-EN en 1406e

The diagram below shows the basic layout of a drive with the
SPC11 using, as an example, a linear unit with a linear poten-
tiometer.

1

2

3

4

5

6

7

8

P.01

P.02

1

Drive (linear unit)

2

Measuring system (here, external
linear potentiometer)

3

Fixed stops

4

Line voltage connection and I/O
coupling (e.g with PLC)

5

Soft Stop SPC11

6

Proportional directional control valve
type MPYE-5-...-...

7

Service unit
(without lubricator, with 5 μm filter)

8

Compressed air source (5 to 7 bar)

Fig. 1/1: Layout of a drive with SPC11 (example linear drive)

With the SPC11, movement is controlled. During commission-
ing, the end positions (cylinder end positions or position of
the fixed stops) as well as the desired intermediate positions
are “learnt” by the SPC11.