2 pre-parameterising in the office, 1 parameters a, c and s, 2 parameters l and r (only with type spc11-inc) – Festo Контроллер крайних положений SPC11 User Manual
Page 66
4. Commissioning
4-8
Festo P.BE-SPC11-SYS-EN en 1406e
4.2
Pre-parameterising in the office
4.2.1 Parameters A, C and S
The permitted values of the parameters A, C, and S for the
drive you are using can be found in the appropriate axis-
specific supplement.
4.2.2 Parameters L and r (only with type SPC11-INC)
The parameters L and r are only queried when incremental
path measuring systems are used (e.g. positioning drive
DNCI-...-... in connection with type SPC11-INC).
With incremental path measuring systems, the SPC11
requires the following information:
–
Nominal stroke length (L) of the drive (see type plate)
–
Offset axis zero point (r) – offset between the end position
P.01 and the axis zero point (see Fig. 4/2).
1
Axis zero point
(piston rod run in
2
Offset axis zero
point (r)
3
Fixed stop
(here for end
position P.01)
1
2
3
P.01
P.02
Fig. 4/2: Reference points for incremental path measuring systems with SPC11-INC