3. Installation
3-13
Festo P.BE-SPC11-SYS-EN en 1406e
With type MME-MTS-...-AIF:
Note
The mechanical work path (possible slide path) of measur-
ing system type MME-MTS-...-AIF is longer than the electri-
cal work path (usable stroke length).
Fit measuring system type MME-MTS-...-AIF so that the elec-
trical work path (see type designation MME-MTS-...-AIF) of the
measuring system is symmetrical to the complete cylinder
stroke.
1
Remaining slide
path
2
Electrical work
path (usable
stroke length)
3
Mechanical work
path (possible
slide path)
1
1
2
3
Fig. 3/6: Usable stroke length with type MME-MTS-...-AIF