beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 134

background image

B. Technical appendix

B-4

Festo P.BE-SPC11-SYS-EN en 1406e

Technical specifications

Type SPC11-...-...

Path measuring system
input
Type SPC11-POT-...

Type SPC11-MTS-AIF

Type SPC11-INC

Potentiometer
– Supply voltage
– Input voltage
MTS Temposonics
– Supply voltage
– Communication
Incremental path measurement
– Sensor supply
– Sensor signals

+10 V
0...+10 V

24 V
CAN field bus

5 V and GND
Are picked up at 2 magnetic
field sensors

Valve output

– Power supply
– Output voltage

24 V (DC)
0...+10 V

CE marking symbol (see conformity declaration)
 www.festo.com

as per EU EMC directive

Vibration and shock

– Vibration

– Shock

– Tested as per DIN/IEC 68/

EN 60068 part 2-6;
0.35 mm path at 10...60 Hz
5 g acceler. at 60...150 Hz

– Tested as per DIN/IEC 68/

EN 60068 part 2-27;
±30 g at 11 ms duration;
5 shocks per direction

1)

The component is intended for industrial use.