beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 56

background image

3. Installation

3-28

Festo P.BE-SPC11-SYS-EN en 1406e

Connection example type SPC11-...-...

Note
With measuring systems type MLO-POT-...-LWG:
In order to earth the system, connect the earthing cable on
the flat plug of the measuring system to the earth connec-
tion on the SPC11.

24 V
0 V

O1: P.01
O2: P.02
O3: P.03
O4: P.04

*)

O5: Error

*)

I1: P.01
I2: P.02

I3: P.03

I4: P.04

*)

I5: +/}

I6: Enter/Teach/Esc
I7: {/–
I8: Remote

15

14
13

12
11
10
9
8
7
6

5
4

3
2
1

white-yellow
brown-green
white-green
red-blue
grey-pink
violet
black

red
blue
pink
grey
yellow

green
brown

white

2

1

3

4

*)

The function of this input/output can be configured (see section 4.2.3).

1

Pin assignment for Control connection
with core colours for cable
KMPV-SUB-D-15-...
O... = output, I... = input

2

Sensors for moving to the positions
(P.04 only for factory setting)

3

With linear drives, end position P.01
lies on the side with the electrical
connection to the measuring system

4

Earth/ground

Fig. 3/15: Connection example type SPC11-...