Festo Контроллер крайних положений SPC11 User Manual
Page 56
3. Installation
3-28
Festo P.BE-SPC11-SYS-EN en 1406e
Connection example type SPC11-...-...
Note
With measuring systems type MLO-POT-...-LWG:
In order to earth the system, connect the earthing cable on
the flat plug of the measuring system to the earth connec-
tion on the SPC11.
24 V
0 V
O1: P.01
O2: P.02
O3: P.03
O4: P.04
*)
O5: Error
*)
I1: P.01
I2: P.02
I3: P.03
I4: P.04
*)
I5: +/}
I6: Enter/Teach/Esc
I7: {/–
I8: Remote
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
white-yellow
brown-green
white-green
red-blue
grey-pink
violet
black
red
blue
pink
grey
yellow
green
brown
white
2
1
3
4
*)
The function of this input/output can be configured (see section 4.2.3).
1
Pin assignment for Control connection
with core colours for cable
KMPV-SUB-D-15-...
O... = output, I... = input
2
Sensors for moving to the positions
(P.04 only for factory setting)
3
With linear drives, end position P.01
lies on the side with the electrical
connection to the measuring system
4
Earth/ground
Fig. 3/15: Connection example type SPC11-...