4. Commissioning
4-26
Festo P.BE-SPC11-SYS-EN en 1406e
3. If fixed stops are used:
Set the fixed stops accurately in the desired end posi-
tions. The positioning stroke permitted for the drive used
can be found in the “Drive-Specific Supplement”.
4. Check whether the parameters have already been
correctly set in pre-commissioning.
The permitted values of the parameters A, C, and S for the
drive you are using can be found in the appropriate
axis-specific supplement. The currently set values will be
shown briefly when the operating voltage is switched on
(see also Fig. 4/4).
If the SPC11 is in the status at delivery:
When the operating voltage is switched on, the SPC11 waits
for the amplification stage (A) to be entered.
S
In this case, set the parameters as described in
section 4.2.5.
If the parameters have already been set:
When the operating voltage is switched on, the SPC11 shows
briefly the set parameters one after the other, so that they can
be checked. The SPC11 then indicates readiness to carry out
the teach procedure (t flashes).
(t flashes)
The teach procedure can now be started (see sections 4.3.2).