4. Commissioning
4-4
Festo P.BE-SPC11-SYS-EN en 1406e
4.1.1 Basic principles of configuring and operating the SPC11
Parameters
The SPC11 must be familiar with certain conditions of use.
These conditions of use are described by the following para-
meters:
Display
Parameters
Description
Amplification stage
Influences the acceleration
behaviour of the drive
Dependent on drive,
valve and mass load;
see Drive-Specific
Supplement
Cushioning stage
Influences the run-in behaviour
when moving to the end positions
and intermediate positions.
System parameters
Characteristic values for setting up
the drive with reference to the drive
type
– First character: Characteristic
value for the ratio of drive and
measuring system length
– Second character: Characteristic
value for the ratio of drive length
and drive diameter.
Nominal stroke-
length of the drive
Nominal stroke length in 1 mm
increments (e.g. nominal stroke
300 mm: L = 300)
Only with the use of an
incremental path
measuring system
1)
(see section 4.2.2)
Offset axis zero point
Offset between the end position
P.01 and the axis zero point in 1 mm
increments
Option parameters
(Options)
Permits various options (e.g. Ready signal instead of Error
signal, Stop signal instead of P.04 etc., see section 4.2.3)
1)
e.g. with drive DNCI-...-... in connection with type SPC11-INC