Manual movement – Festo Контроллер крайних положений SPC11 User Manual
Page 104
4. Commissioning
4-46
Festo P.BE-SPC11-SYS-EN en 1406e
Please note
A position task or stop procedure can be interrupted at
any time and replaced by a new task.
Manual movement
Condition
The drive must be ready for operation. There must be a
0-signal at inputs I1...4. In the procedure using the key-
board, a 0-signal must be present at the input I8 (remote).
The moveable mass can be moved manually with the buttons
{ or }.
Button
Description
{/-
Reduce the position value (the mass moves slowly in
the direction of the measuring system zero point)
+/}
Increase the position value (the mass moves slowly
away from the measuring system zero point)
In order to move the mass manually:
S
Hold the button { or } pressed down for as long as is
required to move the mass.
S
Release the button in order to stop the mass.
The position number flashes to indicate that the current posi-
tion can be saved as the intermediate position if the Enter
button is pressed (see section 4.3.3).