Festo Контроллер крайних положений SPC11 User Manual
Page 75
4. Commissioning
4-17
Festo P.BE-SPC11-SYS-EN en 1406e
cushioning stage will be shown (here 0). This is shown by
the letter C (Cushioning stage).
(C.00)
4. Set cushioning stage with +/-, e.g. 04.
(C.04)
5. Hold the Enter key pressed down
> 2 seconds. The value
will then be transferred and the system parameter shown
(here 0).
(S.00)
6. Set system parameters with +/-, e.g. 01.
(S.01)
7. Hold the Enter key pressed down
> 2 seconds. The value
will then be taken over.
If you do not use an incremental path measuring system,
the option parameter (o.00) is displayed. Then read
further at point 14.
If you use an incremental path measuring system
(e.g. drive DNCI-...-... in connection with type SPC11-INC),
the drive length (nominal stroke) (L) is now queried.
(L.00)
8. Press any desired button to display the drive length in
mm (three-digit number).
(000)
9. Set drive length in mm with +/- (see rating plate), e.g. 300
for 300 mm.