4. Commissioning

4-17

Festo P.BE-SPC11-SYS-EN en 1406e

cushioning stage will be shown (here 0). This is shown by
the letter C (Cushioning stage).

(C.00)

4. Set cushioning stage with +/-, e.g. 04.

(C.04)

5. Hold the Enter key pressed down

> 2 seconds. The value

will then be transferred and the system parameter shown
(here 0).

(S.00)

6. Set system parameters with +/-, e.g. 01.

(S.01)

7. Hold the Enter key pressed down

> 2 seconds. The value

will then be taken over.

If you do not use an incremental path measuring system,
the option parameter (o.00) is displayed. Then read
further at point 14.

If you use an incremental path measuring system
(e.g. drive DNCI-...-... in connection with type SPC11-INC),
the drive length (nominal stroke) (L) is now queried.

(L.00)

8. Press any desired button to display the drive length in

mm (three-digit number).

(000)

9. Set drive length in mm with +/- (see rating plate), e.g. 300

for 300 mm.