1 general instructions on commissioning – Festo Контроллер крайних положений SPC11 User Manual
Page 61
4. Commissioning
4-3
Festo P.BE-SPC11-SYS-EN en 1406e
4.1
General instructions on commissioning
This chapter describes parameterising and commissioning
with the aid of the three buttons on the SPC11. A 1-signal at
the Remote input (I8) blocks the SPC11 buttons. Button func-
tions can then be called up via the digital inputs (I5...7).
Detailed information on this can be found in appendix A.
Warning
During commissioning and during operation the moveable
mass is moved at the highest possible acceleration and
speed. Make sure that:
–
Nobody can place his/her hand in the positioning range
of the moveable mass, unless the compressed air supply
is switched off.
–
The complete positioning range is free collision
contours.
Warning
Incorrectly set parameters can damage the fixed stops and
the drive.
Be very careful when setting the parameters.