3. Installation

3-5

Festo P.BE-SPC11-SYS-EN en 1406e

Compressed air supply ( 1 )

S

Use only dried, non-lubricated, 5 μm filtered compressed
air from 5 to 7 bar.

You will require a service unit with a 5 μm filter for protecting
the proportional directional control valve against damage.

Service unit ( 2 )

S

Use a service unit consisting of a compressed air filter
and a regulating valve (e.g. type LFR-...-D-... with 5 μm
filter element) as well as a safety start-up valve
(e.g. HEL-...-...):

without lubricator

with a 5 μm filter

with sufficiently large standard flow corresponding to
the air requirement of the connected drive during
positioning. Reference value: twice the rated flow of
the valve (type MPYE-5-...), e.g.:

Valve type

Service unit

MPYE-5-1/8-LF-010B

LFR-M1-G1/8-C10RG or
LFR-1/8-D-5M-MINI

MPYE-5-1/8-HF-010B

LFR-M1-G1/4-C10RG or
LFR-1/4-D-5M-MINI

MPYE-5-1/4-010B

LFR-M2-G1/4-C10RG or
LFR-3/8-D-5M-MIDI

MPYE-5-3/8-010B

LFR-M2-G3/8-C10RG or
LFR-3/4-D-5M-MAXI

S

Use a microfilter if you cannot avoid slight oil mist from
the compressed air supply.