beautypg.com

Festo Контроллер крайних положений SPC11 User Manual

Page 65

background image

4. Commissioning

4-7

Festo P.BE-SPC11-SYS-EN en 1406e

Possible status information

Display

Description

When the letter (t) flashes: The SPC11 waits for the teach task.
When the dots (...) flash: The teach procedure is being carried out.

Only with type SPC11-MTS-AIF:
The SPC11 checks whether the measuring system is connected
(find measuring system).

When the SPC11 is switched on:
The moveable mass stands uncontrolled and is not in a taught position (P.01...P.04).
The outputs O1...4 therefore supply a 0-signal.
In operation (e.g. manual positioning):
The moveable mass stands controlled but is not in a taught position (P.01...P.04).
The outputs O1...4 therefore supply a 0-signal.

The moveable mass stands in end position P.01
(end position when measuring system is connected).

The moveable mass stands in end position P.02
(opposite end position).

The moveable mass stands in intermediate position P.03
(taught intermediate position).

The moveable mass stands in intermediate position P.04
(taught intermediate position).

Stop signal over Stop input I4

Fault number (Error; value range: 01...0.19); see chapter 5

Reference travel is being carried out.