5. Diagnosis and error treatment
5-12
Festo P.BE-SPC11-SYS-EN en 1406e
4. With the buttons +/- you can increase or reduce the value
by one stage, in accordance with the positioning char-
acteristics of the drive (see axis-specific supplement).
Hold the Enter key pressed down for at least 2 seconds
(
> 2 s) in order to accept the value. The cushioning stage
will then be shown.
(C.04)
5. With the buttons +/- you can increase or reduce the value
by one stage, in accordance with the positioning char-
acteristics of the drive (see axis-specific supplement).
Hold the Enter key pressed down for at least 2 seconds
(
> 2 s) in order to accept the value. The system parameter
will then be shown.
(S.01)
6. Check and, if necessary, correct the current setting.
Hold the Enter key pressed down for at least 2 seconds
(
> 2 s) in order to accept the value. The next parameter
will then be shown.
7. Check and correct the other parameters:
–
with type SPC11-INC:
– nominal stroke length (L)
– offset axis zero point (r)
–
with all types:
– o-parameter (options).
When the o-parameter is confirmed, the SPC11 displays
readiness to carry out the teach procedure.
The t flashes.