Configuring port parameters, Figure 13: port configuration window – Allied Telesis AT-S39 User Manual
Page 58
Section II: Local and Telnet Management
58
Configuring Port Parameters
To configure the parameter settings for a port on the switch, perform the
following procedure:
1. From the Main Menu, type 1 to select Port Menu.
2. From the Port Menu, type 1 to select Port Configuration.
The following prompt is displayed:
Starting Port to Configure [1 to 24] ->
3. Enter the number of the port you want to configure and press Return.
To configure a range of ports, enter the first port of the range.
The following prompt is displayed:
Ending Port to Configure [1 to 24] ->
4. To configure only one port, enter the same port number here as you
entered in Step 3 and press Return. To configure a range of ports,
enter the last port number in the range.
The Port Configuration window in Figure 13 is displayed.
Figure 13 Port Configuration Window
Allied Telesyn AT-8024 Ethernet Switch
Port Configuration
Configuring Ports 4 to 4
0 - Status .............. Forwarding
1 - Negotiation ......... Auto
4 - Flow Control ........ None
5 - Advertise 10FDX ..... Yes
6 - Advertise 10HDX ..... Yes
7 - Advertise 100FDX .... Yes
8 - Advertise 100HDX .... Yes
9 - MDI/MDIX Mode ....... AUTO
B - Broadcast Control ... 0 - No Broadcast Control
C - Save Configuration Changes
F - Force Renegotiation
X - Reset Port
R - Return to Previous Menu