Configuring the interval timer, Figure 43: broadcast storm control window – Allied Telesis AT-S39 User Manual
Page 154
Section II: Local and Telnet Management
154
Configuring the Interval Timer
To set the interval timer for the broadcast frame control feature, perform
the following procedure:
1. From the Main Menu, type 5 to select System Config Menu.
2. From the System Configuration Menu, type 7 to select Advanced
Configuration.
3. From the Advanced Configuration Menu, type 2 to select Broadcast
Timers Setup.
The Broadcast Storm Control window in Figure 43 is displayed.
Figure 43 Broadcast Storm Control Window
4. Type 1, 2, or 3 and enter a value when prompted.
You can enter a different interval timer for each possible port
speed on the switch: 10, 100, and 1000 Mbps. (1000 Mbps applies
only to GBIC modules in an AT-8024GB switch.) A value for an
interval timer applies to all ports operating at that corresponding
speed.
The values for 10 and 100 Mbps ports are in milliseconds. The
value for 1000 Mbps ports is in microseconds.
The management software will multiple your value as follows:
❑ 10 Mbps - 10x
❑ 100 Mbps - 1x
❑ 1000 Mbps - 100x
Allied Telesyn AT-8024 Ethernet Switch
Broadcast Storm Control
1 - Timer for 10 MB ports ..... 0 milli sec
2 - Timer for 100 MB ports .... 0 milli sec
3 - Timer for 1000 MB ports ... 0 micro sec
C - Save Configuration Changes
R - Return to Previous Menu
Enter your selection?