beautypg.com

Starting a local management session – Allied Telesis AT-S39 User Manual

Page 25

background image

AT-S39 User’s Guide

25

Starting a Local

Management

Session

To start a local management session, perform the following procedure:

1. Connect one end of a straight-through RS232 cable with a DB-9

connector to the RS232 Terminal Port on the switch.

Figure 1 Connecting a Terminal or PC to the RS232 Terminal Port

2. Connect the other end of the cable to an RS-232 port on a terminal or

PC with a terminal emulator program.

3. Configure the terminal or terminal emulator program as follows:

❑ Baud rate: 1200 bps to 115200 bps (default 9600; see Note below)

❑ Data bits: 8

❑ Parity: None

❑ Stop bits: 1

❑ Flow control: None

DE

LINK

MODE

POR

T B

FAUL

T

MASTER

PWR

RS-232 TERMINAL POR

T