Chapter 10 – Allied Telesis AT-MCF2300 User Manual
Page 99

Section II: Installation
99
Chapter 10
Installing the AT-MCF2000AC or
AT-MCF2300AC Power Supply Module
Note
The AT-MCF2000AC and AT-MCF2300AC Modules are the power
supply units for the AT-MCF2000 Chassis and the AT-MCF2300
Chassis, respectively. Before installing a power supply module,
check to be sure you have the correct module for the chassis.
Caution
To maintain adequate airflow and cooling, the AT-MCF2000 Chassis
must have two AT-MCF2000AC Power Supply Modules or one
AT-MCF2000AC Module and one AT-MCF2KFAN Module.
This procedure uses the AT-MCF2000 Chassis for illustration purposes.
For the locations of the power supply slots on the AT-MCF2300 Chassis,
refer to Figure 3 on page 29.
To install the AT-MCF2000AC or AT-MCF2300AC Power Supply Module:
1. Remove the AT-MCF2KPNL2 blank panel from one of the power
supply slots on the chassis by loosening the two captive screws on the
panel with a cross-head screwdriver. You can install the power supply
module in either of the power supply slots.
Figure 43. Removing the Blank Panel from a Power Supply Slot
AT-MCF2KPN
L2
AT-MCF2KPN
L3
1111-a
MA
A