Chapter 21: Verifying the Installation
142
Section II: Installation
AT-MCF2000M Management Module
To verify the installation of the optional AT-MCF2000M Management
Module:
❒
Verify that the Power LED on the module is green.
❒
Verify that the System LED is steady or flashing green.
❒
If the 10/100/1000Base-T Management port is connected to a network
device, check that the port’s L/A (Link/Activity) LED is steady or
flashing green or amber.
❒
If the Stack port is connected to another chassis, verify that the L/A
(Link/Activity) LED for the port is steady or flashing green.
If you encounter any problems, refer to “AT-MCF2000M Management
Module” on page 153.
AT-MCF2000S Stacking Module
To verify the installation of the optional AT-MCF2000S Stacking Module:
❒
View the Chassis ID LEDs to determine the modules number
assignment, set with the DIP switches. If, when you installed the
module, you affixed a label with the module’s ID number to its
faceplate, compare the number on the Chassis ID LEDs with the
number on the label. They should be the same. If they are not, remove
the module and reset the DIP switches.
❒
If the Stack ports are connected to other units, verify that the Link/
Activity LEDs for the ports are steady or flashing green.
If you encounter any problems, refer to “AT-MCF2000S Stacking Module”
on page 155.