Problem 1: The PSU LED is off.

Solution: The power supply module is not receiving power or has failed.
Try the following:

Verify that the module is fully seated in the power supply slot in the
chassis.

Verify that the power cord is firmly connected to the power supply
module and the power source.

Try connecting the power module to another power source, preferably
located on a different circuit.

Verify that the power source is operating properly by plugging a
different device into it.

Verify that the power from the power source meets the operating
specifications of the power supply module, listed in “AT-MCF2000AC
Power Supply Module” on page 173 and “AT-MCF2300AC Power
Supply Module” on page 173.

Replace the power supply module.

Problem 2: The PSU LED is amber.

Solution: The power supply module is failing or the power from the power
source is not in the range of the operating specifications of the module.
Try the following:

Try connecting the power module to another power source, preferably
located on a different circuit.

Verify that the power from the power source is within the operating
specifications of the power supply module, listed in “AT-MCF2000AC
Power Supply Module” on page 173 and “AT-MCF2300AC Power
Supply Module” on page 173.

Replace the power supply module.

Problem 3: The FAN LED is amber.

Solution: A fan in the power supply module has failed. Replace the
module.