Link act, Sd rdy busy – Allied Telesis AT-MCF2300 User Manual
Page 132

Chapter 19: Cabling the AT-MCF2000M and AT-MCF2000S Modules
132
Section II: Installation
2. To build a management stack, connect a standard straight-through or
crossover TIA/EIA 568-B-compliant Enhanced Category 5 (Cat 5e)
shielded or unshielded cabling with 100 ohm impedance to the Stack
port. Connect the other end of the cable to either of the Stack ports on
the AT-MCF2000S Stacking Module in the next chassis as shown in
Figure 76. The maximum distance of a stacking cable is 100 meters
(328 ft.).
Figure 76. Cabling the AT-MCF2000M Management Module to the
AT-MCF2000S Stacking Module
3. To connect two AT-MCF2000S Stacking Modules, use a standard
straight-through or crossover TIA/EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or unshielded cabling with 100 ohm
impedance. Connect one of the Stack ports on one module to either of
the Stack ports on the module in the next chassis. All port
combinations are supported, as illustrated in Figure 77. For
background information, refer to Chapter 5, “AT-MCF2000S Stacking
Module” on page 73.
AT-MCF2000S
LINK
ACT
PORT ACTIVITY
STACK 1
STACK 2
AT-MCF2000S
LINK
ACT
PORT ACTIVITY
STACK 1
STACK 2
AT-MCF2000M
STACK
MANAGEMENT
TERMINAL
10/100/1000BASE-T
RS-232
RESET
SD
RDY
BUSY
MASTER
POWER
BOOT
RDY
FAULT
1000 LINK
ACT
10/100 LINK
ACT
FDX
HDX
COL
LINK
ACT
PORT ACTIVITY
SYSTEM
0
31
ID
AT-MCF2000M
STACK
MANAGEMENT
TERMINAL
10/100/1000BASE-T
RS-232
RESET
SD
RDY
BUSY
MASTER
POWER
BOOT
RDY
FAULT
1000 LINK
ACT
10/100 LINK
ACT
FDX
HDX
COL
LINK
ACT
PORT ACTIVITY
SYSTEM
0
31
ID
CHASSIS ID
CHASSIS ID
1259
OR
AT-MCF2000M Management
Module
AT-MCF2000S Stacking
Module