Fiber optic ports, Table 6: fiber optic ports – Allied Telesis AT-MCF2300 User Manual
Page 36

Chapter 3: AT-MCF2012LC, AT-MCF2012LC/1 and AT-MCF2032SP Modules
36
Section I: Features
Fiber Optic Ports
Table 6 lists the specifications for the fiber optic cabling for the
AT-MCF2012LC and AT-MCF2012LC/1 Media Converter Modules.
Note
The maximum operating distances in the table assume full-duplex
operation. The maximum operating distance of a fiber optic port
operating in half-duplex mode will be significantly less.
For the operating specifications of the fiber optic ports on the
AT-MCF2012LC and AT-MCF2012LC/1 Modules, refer to “100Base-FX
Fiber Optic Ports” on page 175.
For the fiber optic cabling specifications for the AT-MCF2032SP Module,
refer to the instructions that come with the SFP modules.
Table 6. Fiber Optic Ports
Media Converter
Module
Connector
Maximum
Operating
Distance
Fiber Optic Cable
AT-MCF2012LC
Duplex LC
2 km (1.24 mi.)
50/125 µm or 62.5/125 µm
(core/cladding) multimode
fiber optic cable
AT-MCF2012LC/1
Duplex LC
20 km (12.4 mi.)
9/125 µm single-mode fiber
optic cable