Appendix C: Cleaning Fiber Optic Connectors

184

Using a Swab

Specially treated swabs (stick cleaners) are available for cleaning inside
connector adapters or hard-to-reach ferrule tips. These swabs, often
referred to as “lint free” or “alcohol free” swabs, are available from many
vendors, as shown in Figure 107. Stick cleaners are available in both 2.5
mm and 1.25 mm sizes for use on SC and MU connectors respectively.

Note

NEVER use a household cotton swab and/or alcohol to clean a fiber
optic connector. This may leave a residue on the ferrule tip.

Figure 107. Lint-Free and Alcohol-Free Swabs

Note

Do not use compressed air or aerosol air to clean a fiber optic
connector.

To clean a recessed ferrule using a swab.

1. Insert the swab into the adapter as shown in Figure 108 and rub the

ferrule tip with the swab.

Figure 108. Cleaning a Recessed Ferrule

Warning: Do not stare into the laser beam.

L2

Warning: Do not look directly at the fiber optic cable ends or
inspect the cable ends with an optical lens.

E29

157