HP VMA SAN Gateway User’s Guide

AM456-9026A

unexpected-
shutdown

Event

Triggered

A HP VMA SAN
Gateway has
unexpectedly
shutdown. This may
happen during a
software upgrade when
the upgrade did not
cleanly apply and the
system reverted back
to the previous version
prior to upgrade. A
callhome event is
generated.

Please contact HP
customer support.

High

user-login

Event

Triggered

A login to a HP VMA
SAN Gateway via
either the CLI or Web
UI has occurred.

Verify the user id
has not been
compromised.

Low

user-logout

Event

Triggered

A logout from a HP
VMA SAN Gateway
via either the CLI or
Web UI has occurred.

Check that the
appropriate settings
for auto-logout are
configured for the
user. There are
separate settings for
the CLI vs. Web UI.

Low

vimm-state-change

State Change

State

One or more VIMMs
have changed state on
a HP Array. A comma
separated list of
VIMMs are provided
for each state:
admin_down, booting,
active, spare, failed,
present, or alarmed.
The set value for each
VIMM list / state
change is “true” for set
or “false” for clear.

Check the HP VMA
Array for alarms to
determine severity
of state change.

High /
Low

vimm-temperature-
high

80

Celsius

VIMM temperature
has exceeded normal
operating range

Check VMA array
airflow and
operating
environment.

High

vimm-temperature-
ok

75

Celsius

VIMM temperature
has dropped into
normal operating range

Nothing.

Low

Trap Name

Threshold

Value Unit

Description

Solution

Sev.