beautypg.com

HP VMA-series Memory Arrays User Manual

Page 237

background image

AM456-9026A

HP VMA SAN Gateway User’s Guide

237

array-psu-state

State Change

State

An Array has changed
state regarding one or
both of the Power
Supply Units. A true or
false value for psuA
and psuB specifies
whether the old / new
values are different.
The PSU state can be:
Absent, ON, or OFF.

Check the power
source to the Array
power supplies.

High /
Low

array-raid-rebuild

State Change

0 or 1

An Array has changed
state regarding VIMM
RAID group rebuild. A
new value of 1
specifies that a RAID
rebuild is in progress
and that performance
will be affected. A new
value of 0 specifies
that the RAID rebuild
has completed.

If the new value is
1, check the Array
alarms for a failed
VIMM and contact
HP support for a
possible
replacement.

Medium

chassis-temperature-
high

75

Celsius

Temperature inside an
Array chassis has
exceeded normal
operating range

Check airflow and
operating
environment.

High

chassis-temperature-
ok

70

Celsius

Temperature inside a
Array chassis has
dropped into normal
operating range

Nothing.

Low

cpu-util-high

98

Percent

A HP VMA SAN
Gateway has detected
that a CPU has
exceeded utilization
above the threshold
level

Please contact HP
customer support if
this situation
continues and the
system is not under
full data traffic load.

Low

disk-io-high

5120

KBytes /
sec

The internal disk on a
HP VMA SAN
Gateway has crossed a
threshold for
performing too many I/
O’s per second.

If the system is not
under data traffic
load, please contact
HP customer
support.

Low

disk-space-low

0

Percent
Free

A HP VMA SAN
Gateway disk space
has crossed the
threshold of percent of
bytes free.

Please contact HP
customer support.

Medium

Trap Name

Threshold

Value Unit

Description

Solution

Sev.