process-crash

Event

Triggered

An internal process on
a HP VMA SAN
Gateway has crashed.
A callhome event is
generated with the
details of the event.

Please contact HP
customer support.

High

process-exit

Event

Triggered

An internal process on
a HP VMA SAN
Gateway has
unexpectedly exited. A
callhome event is
generated with the
details of the event.

Please contact HP
customer support.

High

unexpected-cluster-
join

Event

Triggered

A HP VMA SAN
Gateway has
unexpectedly joined a
management group
after the 180 seconds
cluster startup time has
elapsed.

Check the HP VMA
SAN Gateway log
for any errors.
Please contact HP
customer support if
the join event is
unexplained.

Low

unexpected-cluster-
leave

Event

Triggered

A HP VMA SAN
Gateway has
unexpectedly left a
management group
after already being a
member.

Check power and
network
connectivity to the
missing VMA SAN
Gateway. Please
contact HP
customer support if
the leave event is
unexplained.

High

unexpected-cluster-
size

Expected
Nodes

Node
count

After a management
group startup time of
180 seconds has
elapsed, the number of
detected nodes should
match cluster
expected-nodes
configured. This trap is
sent when the number
of nodes has changed
and is not the expected
value.

Use the CLI to
configure “cluster
expected-nodes” to
set the appropriate
value.

Low

Trap Name

Threshold

Value Unit

Description

Solution

Sev.