beautypg.com

Vring – HP VMA-series Memory Arrays User Manual

Page 222

background image

222

HP VMA SAN Gateway User’s Guide

AM456-9026A

vring

The

vring

utility debugs the internal HP VMA Array I/O request ring at a low level, and checks

for unaligned flash device access.

Look for the transfer sizes under the column labeled

SIZE

. If most of the lines show

4096

, full 4kB

accesses are being done to the HP VMA Array hardware, which is optimal. In an unaligned access

case, you will see lines alternate between

512

and

3584

for transfer size, since two read-modify-

write operations occur for each 4kB of data.

Syntax

vring [ -p ]

Completed write I/O's

Displays the total I/O write requests to a HP
VMA Array. This is not the individual DMA
descriptors completed, but for each of the user
requested I/Os.

Unaligned host buf
writes

Displays the total I/O write requests to a HP
VMA Array, but only incremented when an
unaligned host address required special buffer
byte copying to service the DMA request.

Flash partial page
writes

Increments when a DMA descriptor for write
is less than a flash page (4kB) in size, which
leads to a hardware read-modify-write
operation.