Vring – HP VMA-series Memory Arrays User Manual
Page 222

222
HP VMA SAN Gateway User’s Guide
AM456-9026A
vring
The
vring
utility debugs the internal HP VMA Array I/O request ring at a low level, and checks
for unaligned flash device access.
Look for the transfer sizes under the column labeled
SIZE
. If most of the lines show
4096
, full 4kB
accesses are being done to the HP VMA Array hardware, which is optimal. In an unaligned access
case, you will see lines alternate between
512
and
3584
for transfer size, since two read-modify-
write operations occur for each 4kB of data.
Syntax
vring [ -p
Completed write I/O's
Displays the total I/O write requests to a HP
VMA Array. This is not the individual DMA
descriptors completed, but for each of the user
requested I/Os.
Unaligned host buf
writes
Displays the total I/O write requests to a HP
VMA Array, but only incremented when an
unaligned host address required special buffer
byte copying to service the DMA request.
Flash partial page
writes
Increments when a DMA descriptor for write
is less than a flash page (4kB) in size, which
leads to a hardware read-modify-write
operation.