beautypg.com

HP VMA-series Memory Arrays User Manual

Page 240

background image

240

HP VMA SAN Gateway User’s Guide

AM456-9026A

media-device-state-
change

State Change

State

A HP VMA SAN
Gateway media device
(Array) has changed
state. The possible
states are: unknown,
online, offline, error,
removed, disabled, or
onlining.

Verify that the
connected Array is
in the proper online
state.

High /
Low

media-device-
unknown-type

Event

Triggered

A HP VMA SAN
Gateway has detected a
media device
connected of an
unknown type. The
Model, Serial #, and
size are provided.

The most common
occurrence is a
freshly formatted
Array has been
connected to a HP
VMA SAN
Gateway. The CLI
“media init ...”
command is used to
initialize the device.

Low

media-system-swap-
state

State Change

State

An internal SAN
Gateway disk has
changed state for
having an active swap
partition. The active
state is true when a
swap partition has
been activated or false
for deactivation.

Please contact HP
customer support.

Low

memusage-high

90

Percent

A HP VMA SAN
Gateway has detected
that system RAM has
exceeded a percentage
in use threshold.

Please contact HP
customer support.

Medium

netusage-high

10485760

Bytes / sec

A HP VMA SAN
Gateway has detected
that a network
interface has exceeded
a bytes per second
threshold.

Please verify your
network
configuration.

Low

paging-high

2000

Duration /
sec

Memory paging on a
HP VMA SAN
Gateway has exceeded
a threshold.

Please contact HP
customer support if
the system is not
under full data
traffic load.

Medium

Trap Name

Threshold

Value Unit

Description

Solution

Sev.