beautypg.com

Initiator group commands, Create an initiator group, Add initiators to a group – HP VMA-series Memory Arrays User Manual

Page 204: Lun commands, View luns

background image

204

HP VMA SAN Gateway User’s Guide

AM456-9026A

The command returns the node, hostname, target port, status (enabled or not), and address (WWN).

The

detail

parameter returns the network bindings for each target.

Initiator Group Commands

This section provides the syntax for initiator group commands, along with an explanation of the

functionality of each command.

Create an Initiator Group

[no] igroup create name

The

igroup create

command creates an initiator group, after which you can add initiators using

the

addto

command. For more information, see Add Initiators to a Group on page 204.

Add Initiators to a Group

[no] igroup addto initiators [initiator_name …]

The

igroup addto

command adds one or more Fibre Channel initiators. Fibre Channel initiator

identifiers (WWNs) are generated automatically by a Host Bus Adapter (HBA).

LUN Commands

This section provides the syntax for LUN commands, along with an explanation of the functionality

of each command.

View LUNs

show luns container name sessions

> enable
# show targets
Node Hostname Proto Target Enab Address
----------------------------------------------------------------------
--------
1 lab-n1 fc hba-a1 yes wwn.21:00:00:1b:32:9b:83:3b
1 lab-n1 fc hba-a2 yes wwn.21:01:00:1b:32:bb:83:3b
n1:targ2
2 lab-n2 fc hba-a1 yes wwn.21:00:00:1b:32:9f:f3:ce
2 lab-n2 fc hba-a2 yes wwn.21:01:00:1b:32:bf:f3:ce

This manual is related to the following products: