CONFIGURATION

95

Falling voltage slew rate F-05

0.001~0.06V/msec (PSU 6-200)
0.001~0.125V/msec (PSU 12.5-120)
0.001~0.2V/msec (PSU 20-76)
0.001~0.4V/msec (PSU 40-38)
0.001~0.6V/msec (PSU 60-25)

Rising current slew rate F-06

0.001~2A/msec (PSU 6-200)
0.001~1.2A/msec (PSU 12.5-120)
0.001~0.76A/msec (PSU 20-76)
0.001~0.38A/msec (PSU 40-38)
0.001~0.25A/msec (PSU 60-25)

Falling current slew rate F-07

0.001~2A/msec (PSU 6-200)
0.001~1.2A/msec (PSU 12.5-120)
0.001~0.76A/msec (PSU 20-76)
0.001~0.38A/msec (PSU 40-38)
0.001~0.25A/msec (PSU 60-25)

Internal resistance
setting

F-08

0~0.03Ω (PSU 6-200)
0~0.104Ω (PSU 12.5-120)
0~0.263Ω (PSU 20-76)
0~1.053Ω (PSU 40-38)
0~2.4Ω (PSU 60-25)

Bleeder circuit control

F-09

0 = OFF, 1 = ON

Buzzer ON/OFF control F-10

0 = OFF, 1 = ON

OCP Delay Time

F-12

0.1 ~ 2.0 sec

Current Setting Limit
(I-Limit)

F-13

0 = OFF, 1 = ON

Voltage Setting Limit
(V-Limit)

F-14

0 = OFF, 1 = ON

Display memory
parameter when recalling
(M1, M2, M3)

F-15

0 = OFF, 1 = ON

Auto Calibration Parallel
Control

F-16

0 = Disable, 1 = Enable, 2 = Execute
Parallel Calibration and set to Enable.
Note: Must be a short between each
unit before starting.

Measurement Average
Setting

F-17

0 = Low, 1 = Middle, 2 = High

Alarm Recovery and
Output Status

F-18

0 = Safe Mode, 1 = Force Mode