beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 143

background image

ANALOG CONTROL

143

Isolated External Voltage Control of Voltage Output

Background

Voltage control of the voltage output uses the
isolated voltage option (PSU-ISO-V). A voltage
of 0~5V or 0~10V is used to control the full
scale voltage of the instrument, where:

For 0~5V: Output voltage = full scale voltage ×
(external voltage/5)

For 0~10V: Output voltage = full scale voltage ×
(external voltage/10)

Connection

When connecting the external voltage source to
the isolated voltage option, use shielded or
twisted paired wiring.

PSU

EXT-V

Isolated

Voltage

Option

4

2

Output

Terminal

2 core shielded

wire or twisted

pair

1or8

Pin4(GND_ISO) → EXT-V (-)

Pin2(+VPROG_ISO) → EXT-V (+)

Pin 1 or 8 (Shield) → Wire shield