beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 108

background image

PSU Series User Manual

108

F-92

0 = Safe Mode (Always OFF),
1 = Force Mode (Always ON),
2 = Auto Mode (Status before

last time Power OFF)

Master/Slave
Configuration

Sets the power supply as master or slave. See
the parallel/series operation for details, page
68.

F-93

0 = Independent
1 = Master with 1 slave in

parallel

2 = Master with 2 slaves in

parallel

3 = Master with 3 slaves in

parallel

4 = Slave (parallel)

External Output
Logic

Sets the external logic as active high or low for
analog control pin 19.
F-94

0= High ON, 1 = Low ON

Monitor Voltage
Select

Selects the voltage monitor output range.

F-96

0 = 5V, 1 = 10V

Control Range

Selects the external control range for external
voltage or resistance control.

F-97

0 = 5V [5kΩ], 1 = 10V [10kΩ]

External Output
Control Function

Set external output control on or off.

F-98