94

Configuration Overview

Configuration of the PSU power supplies is divided into five
different configuration settings: Normal Function, USB/GPIB, LAN,
UART, System Configuration Settings, Power ON Configuration
and Special Function Settings. Power ON Configuration differs
from the other settings in that the settings used with Power ON
Configuration settings can only be set during power up. The other
configuration settings can be changed when the unit is already on.
This prevents some important configuration parameters from being
changed inadvertently. Power On Configuration settings are
numbered F-90 to F-98 and the other configuration settings are
numbered F-00 to F-61, F-70 to F-76 and F-88 to F-89. The Special
Function Settings are used for calibration, firmware updated and
other special functions; these functions are not supported for end-
user use.

Configuration Table

Please use the configuration settings listed below when applying
the configuration settings.

Normal Function
Settings

Setting Setting Range

Output ON delay time

F-01

0.00s~99.99s

Output OFF delay time F-02

0.00s~99.99s

V-I mode slew rate select F-03

0 = CV high speed priority (CVHS)
1 = CC high speed priority (CCHS)
2 = CV slew rate priority (CVLS)
3 = CC slew rate priority (CVLS)

Rising voltage slew rate F-04

0.001~0.06V/msec (PSU 6-200)
0.001~0.125V/msec (PSU 12.5-120)
0.001~0.2V/msec (PSU 20-76)
0.001~0.4V/msec (PSU 40-38)
0.001~0.6V/msec (PSU 60-25)