beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 126

background image

PSU Series User Manual

126

5kΩ~0kΩ/10kΩ~0kΩ.

Rising:
For 0kΩ~10kΩ: Output current = full scale
current × (external resistance/10)

For 0kΩ~5kΩ: Output current = full scale
current × (external resistance/5)

Falling:
For 10kΩ~0kΩ: Output current = full scale
current × ([10-external resistance]/10)

For 5kΩ~0kΩ: Output current = full scale
current × ([5-external resistance]/5)

Note

The falling resistance configuration is
recommended for safety reasons. In the event that
the cables become accidentaly disconnected, the
current output will drop to zero (high Ω). Under
similar circumstances using the rising
configuration, an unexpectedly high current would
be output.

If swtiches are used to switch between fixed
resistances, use switches that avoid creating open
circuits. Use short-circuit or continous resistance
switches.

Connection

PSU

EXT-R

Analog

connector

23

21

Output

Terminal

2 core shielded

wire or twisted

pair

Pin21 → EXT-R

Pin23 → EXT-R

Wire shield → negative (-) output terminal