beautypg.com

Front panel – GW Instek PSU-Series User Manual User Manual

Page 190

background image

PSU Series User Manual

190

Front Panel

Model

PSU 6-200

12.5-120

20-76 40-38 60-25

Display, 4 digits

Voltage accuracy

0.1% + mV

12

25

40

80

120

Current accuracy

0.2% + mA

600

360

228

114

75

Indications

GREEN LED's: CV, CC, V, A, VSR, ISR, DLY,
RMT, LAN, M1, M2, M3, RUN, Output ON

RED LED's: ALM, ERR

Buttons

Lock/Local(Unlock), PROT(ALM_CLR),

Function(M1), Test(M2), Set(M3), Shift,
Output

Knobs

Voltage, Current

USB port

Type A USB connector

Programming and Measurement (RS-232/485, USB, LAN,
GPIB)

Model

PSU

6-200 12.5-120 20-76 40-38 60-25

Output voltage
programming
accuracy

0.05% + mV

3

6.25

10

20

30

Output current
programming
accuracy

0.2% +

mA

200

120

76

38

25

Output voltage
programming
resolution

mV

0.2

0.4

0.7

1.3

2

Output current
programming
resolution

mA

6

4

2.5

1.2

0.8

Output voltage
measurement
accuracy

0.1% +

mV

6

12.5

20

40

60

Output current
measurement
accuracy

0.2% +

mA

400

240

152

76

50

Output voltage
measurement
resolution

mV

0.2

0.4

0.7

1.3

2

Output current
measurement
resolution

mA

6

4

2.5

1.2

0.8