beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 146

background image

PSU Series User Manual

146

Isolated External Voltage Control of Current Output

Background

Voltage control of the current output uses the
isolated voltage option (PSU-ISO-V). A voltage
of 0~5V or 0~10V is used to control the full
scale current of the instrument, where:

For 0~5V: Output current = full scale current ×
(external voltage/5)

For 0~10V: Output current = full scale current ×
(external voltage/10)

Connection

When connecting the external voltage source to
the isolated voltage option, use shielded or
twisted paired wiring.

PSU

EXT-V

Isolated

Voltage

Option

4

3

Output

Terminal

2 core shielded

wire or twisted

pair

1or8

Pin4(GND_ISO) → EXT-V (-)

Pin3(+IPROG_ISO) → EXT-V (+)

EXT-V ground (Shield) → Wire shield