beautypg.com

Power on configuration settings – GW Instek PSU-Series User Manual User Manual

Page 107

background image

CONFIGURATION

107

Power On Configuration Settings

CV Control

Sets the constant voltage (CV) control mode
between local and external voltage/resistance
control. For external voltage control, see page
118 (External Voltage Control of Voltage
Output) and
page 123 (External Resistance
Control of Voltage Output).
For Isolated
control, see page 140 for details.

F-90

0= Control by local
1 = Control by external voltage
2 = Control by external resistor -

rising

3 = Control by external resistor-

falling

4 = Control by isolated board

CC Control

Sets the constant current (CC) control mode
between local and external voltage/resistance
control. For details on external voltage control,
see page 121 (External Voltage Control of
Current Output) and
125 (External Resistance
Control of Current Output).
For Isolated
control, see page 140 for details.

F-91

0 = Control by local
1 = Control by external voltage
2 = Control by external resistor -

rising

3 = Control by external resistor-

falling

4 = Control by isolated board

Output Status
when Power-ON
Output

Sets the power supply to turn the output on or
off at power up.