OPERATION

65

the isolation voltage of the power supply.

Never connect sensing cables when the output is
on. Electric shock or damage to the power supply
could result.

Note

Be sure to remove the sense jumpers from the
remote sense connector so the unit is not using
local sensing.

Single Load

1. Connect the S+ terminal to the positive

potential of the load. Connect the S- terminal to
the negative potential of the load.

Output

S+

S-

PSU

Output

Load

Input

Input

Page 62

2. Operate the instrument as normal.

See the Basic Operation chapter for
details.

Page 51

Parallel PSU
Units

1. Connect the S+ terminals to the positive

potential of the load. Connect the S- terminals
to the negative potential of the load.