OPERATION

55

4. Use the Current knob to set the F-

03 setting.

Set F-03 to 0 (CV High Speed
Priority) or 2 (CV Slew Rate
Priority).

Current

F-03

0 = CV High Speed Priority
2 = CV Slew Rate Priority

5. Press the Voltage knob to save the

configuration setting. ConF will be
displayed when it is configuring.

Voltage

VOLTAGE

CURRENT

VSR

LAN

RMT

ERR

DLY

ALM

ISR

M 1

M 2

M 3

RUN

C V

C C

V

A

VSR indicator for CV Slew

Rate Priority (F-03=2)

6. If CV Slew Rate Priority was chosen as the

operating mode, set F-04 (Voltage Slew Rate
Up) and the F-05 (Voltage Slew Rate Down)
and save.

F-04 / F-05 0.001V~0.06V/msec (PSU 6-200)

0.001V~0.125V/msec (PSU 12.5-120)
0.001V~0.2V/msec (PSU 20-76)
0.001V~0.4V/msec (PSU 40-38)
0.001V~0.6V/msec (PSU 60-25)

7. Press the Function key again to exit

the configuration settings. The
function key light will turn off.

Function

8. Use the Current knob to set the

current limit (crossover point).

Current