OPERATION

53

2. The OVP protection function will be displayed

on the voltage display and the setting will be
displayed on the current display.

Protection

function

VOLTAGE

CURRENT

VSR

LAN

RMT

ERR

DLY

ALM

ISR

M 1

M 2

M 3

RUN

C V

C C

V

Protection

setting

A

Choose a
Protection
Function

3. Use the Voltage knob to select a

protection function.

Voltage

Range

OVP, OCP, UVL

Setting the
Protection Level

4. Use the Current knob to set the

protection level for the selected
function.

Current

Setting Range

PSU Model OCP

OVP

UVL

6-200

5~220

0.6~6.6

0~6.3

12.5-120

5~132

1.25~13.75 0~13.12

20-76

5~83.6

2~22

0~21

40-38

3.8~41.8

4~44

0~42

60-25

2.5~27.5

5~66

0~63

5. Press PROT again to exit. The

PROT key light will turn off.

PROT

Clear
OVP/OCP/UVL
protection

The OVP, OCP or UVL protection
can be cleared after it has been
tripped by holding the ALM_CLR
button for 3 seconds.

PROT

ALM_CLR