beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 124

background image

PSU Series User Manual

124

Falling:
For 10kΩ~0kΩ: Output voltage = full scale
voltage × ([10-external resistance]/10)

For 5kΩ~0kΩ: Output voltage = full scale
voltage × ([5-external resistance]/5)

Note

The falling resistance configuration is
recommended for safety reasons. In the event that
the cables become accidentaly disconnected (high
Ω), the voltage output will drop to zero. Under
similar circumstances using the rising resistance
configuaration, an unexpectedly high voltage
would be output.

If swtiches are used to switch between fixed
resistances, use switches that avoid creating open
circuits. Use short-circuit or continous resistance
switches.

Connection

PSU

EXT-R

Analog

connector

23

22

Output

Terminal

2 core shielded

wire or twisted

pair

Pin22 → EXT-R

Pin23 → EXT-R

Wire shield → negative (-) output terminal

Steps

1. Connect the external resistance according to the

connection diagrams above.

2. Set the F-90 (CV Control)

configuration settings to 2 for
Ext-R rising or 3 for Ext-R falling.

Page 111