Psu series user manual, Slave units – GW Instek PSU-Series User Manual User Manual

Page 76

background image

PSU Series User Manual

76

Note

Configuration settings can be checked on both the
master and slave units by pressing the Function key
and checking F-93.

Only the Master OVP, OCP and UVL settings are
used for protection. Slave protection levels are
disregarded.

OHP works independently for each unit.

Master-Slave
Operation

Only operate the power supplies in parallel if
the units are configured correctly.

Steps

1. Turn on the master and slave units. The slave

unit(s) will show a blank display.

Master unit

VOLTAGE

CURRENT

VSR

LAN

RMT

ERR

DLY

ALM

ISR

M 1

M 2

M 3

RUN

C V

C C

V

A

Slave units

VOLTAGE

CURRENT

VSR

LAN

RMT

ERR

DLY

ALM

ISR

M 1

M 2

M 3

RUN

C V

C C

V

A

2. Operation of all units is controlled

via the master unit. Operation of
the master unit is the same as for a
single unit. See the Basic Operation
chapter.

Page 51.

3. Press the Output key to

begin. The output LED will
become lit.

Output

Caution

Only operate the power supplies in parallel if using
units of the same model number.

Note

The panel controls are disabled on slave units,
including the output key. On slave units, only the
Function key can be used to view the current
settings.