beautypg.com

GW Instek PSU-Series User Manual User Manual

Page 149

background image

ANALOG CONTROL

149

Connection

When connecting the external current source to
the isolated analog option, use shielded or
twisted paired wiring.

PSU

EXT-I

Isolated

Current

Option

4

2

Output

Terminal

2 core shielded

wire or twisted

pair

1or8

Pin4(GND_ISO) → EXT-I (-)

Pin2(+VPROG_ISO) → EXT-I (+)

Pin 1 or 8 (Shield) → Wire shield

Connection- alt.
shielding

If the wire shield needs to be grounded at the
current source (EXT-I), then it can be connected
as shown below.

PSU

EXT-I

Isolated

Current

Option

4

2

Output

Terminal

2 core shielded

wire or twisted

pair

Pin4(GND_ISO) → EXT-I (-)

Pin2(+VPROG_ISO) → EXT-I (+)

EXT-I ground (GND) → Wire shield

Panel operation

1. Connect the external current source according

to the connection diagrams above.