Note

When using a switch over long distances, please
use a switch relay to extend the line from the coil
side of the relay.

Switch

Relay

Line

extention

Analog

connector

Output

Terminal

20

7

If a single switch control is to be used for multiple
units, please isolate each instrument. This can be
achieved by using a relay.

Warning

Ensure the cables and switch used exceed the
isolation voltage of the power supply. For example:
insulation tubes with a withstand voltage higher
than the power supply can be used.