Page 142: Isolated current connector

background image

PSU Series User Manual

142

Isolated Analog Control Option Overview

Overview

The Isolated Analog Connectors are 8 pin
sockets that are optically isolated from the
power supply, allowing inputs with ground
references that differ to the power supply. The
isolated options include either an isolated
voltage (0~5V/0~10V) interface or an isolated
current (4~20mA) interface. Only one type of
isolated interface can be used at any one time.
The pins used determine what remote control
mode is used.

Note

The GPIB Option (PSU-GPIB), the isolated voltage
option (PSU-ISO-V) and the isolated current
option (PSU-ISO-I) all use the same option slot,
meaning that only one of the three options can be
used at any one time.

Pin Assignment

Isolated Voltage
Connector

8

7

6

5

4

3

2

1

0 - 5V / 0 - 10V

ISOLATED PROGRAMMING

Isolated Current
Connector

8

7

6

5

4

3

2

1

4 - 20mA

ISOLATED PROGRAMMING

Pin name

Pin number

Description

SHIELD

1 Shield, connected internally to the chassis of the

power supply.

+VPROG_ISO

2 Output Voltage programming input.

+IPROG_ISO

3 Output Current programming input.

GND_ISO

4 Ground for programming signals.

GND_ISO

5 Ground for programming signals.

+VMON_ISO

6 Output Voltage monitoring output.

+IMON_ISO

7 Output Current monitoring output.

Shield