Internal resistance – GW Instek PSU-Series User Manual User Manual
Page 26
PSU Series User Manual
26
some time and be potentially hazardous.
In addition, bleed resistors also allow for
smoother voltage regulation of the power
supply as the bleed resistor acts as a minimum
voltage load.
The bleed resistance can be turned on or off
using the configuration settings.
Note
By default the bleed resistance is on. For battery
charging applications, be sure to turn the bleed
resistance off as the bleed resistor can discharge
the connected battery when the unit is off.
Internal Resistance
Background
On the PSU, the internal resistance of the
power supply can be user-defined in software.
(Internal Resistance Setting, see the Normal
Function Settings on page 99.) When the
internal resistance is set it can be seen as a
resistance in series with the positive output
terminal. This allows the power supply to
simulate power sources that have internal
resistances such as lead acid batteries.
By default the internal resistance is 0Ω.
Internal
Resistance Range
Unit Model
Internal Resistance Range
PSU 6-200
0.000 ~ 0.030Ω
PSU 12.5-120
0.000 ~ 0.104Ω
PSU 20-76
0.000 ~ 0.263Ω
PSU 40-38
0.000 ~ 1.053Ω
PSU 60-25
0.000 ~ 2.400Ω