The Level Setting screen is only available when running in leveling

mode. It is used to configure all of the settings for performing a level

loop.
BS1…BSn>FS1…FSn: This sequence requires that you

take all the shots for each set to the backsight, turn to
the foresight, and then shoot all the shots for each set to

the foresight.
[BS1 FS1>FS2 BS2]n: A single set in this sequence
requires that you shoot the backsight, turn and shoot the

foresight, shoot the foresight again, turn and shoot the
backsight. Repeat for all remaining sets.
Number of Sets (n): is the number of sets you want to
shoot from each setup.
Stadia Constant: is the scale of the upper and lower
stadia (wires) in the telescope. The vertical distance

measured between these stadia multiplied by the value
entered here (usually 100) equals the horizontal distance

to the rod.
V Dist Tolerance: is the maximum change in vertical distance that
can occur between all the shots to any specific point from a single

setup. If this value is exceeded, a warning will occur.
H Dist Tolerance: is the maximum change in horizontal distance
that can occur between all the shots to any specific point from a single

setup. If this value is exceeded, a warning will occur.

; BS-FS Sight Length < Per Shot

: When checked, a warning will

occur whenever the horizontal distance of each leg in any given setup

differs by more than this value.

; BS-FS Sight Length < Per Loop

: When checked, the sum of the

horizontal distances measured to all the backsight shots are
compared to the sum of the horizontal distances to all the foresight

shots. If the difference exceeds this value, a warning will occur.

; Max Sight Lengths

: When checked, a warning will occur

whenever the horizontal distance measured to any point exceeds this
value.